Estudio de compatibilidad electromagnética de implante ocular activo para tratamiento de glaucoma utilizando métodos computacionales y experimentales

Fil: Schaumburg, Federico. Universidad Nacional del Litoral. Facultad de Ingeniería y Ciencias Hídricas; Argentina.

Guardado en:
Detalles Bibliográficos
Autor Principal: Schaumburg, Federico
Otros Autores: Guarnieri, Fabio Ariel
Formato: Tesis
Lenguaje:Spanish
Spanish
Publicado: 2017
Materias:
Acceso en línea:http://hdl.handle.net/11185/941
id oai:bibliotecavirtual.unl.edu.ar-handle:11185-941
recordtype dspace
institution Universidad Nacional del Litoral
collection Biblioteca de tesis
language Spanish
Spanish
topic Glaucoma
Electromagnetic compatibility
Dosimetry
Radiated susceptibility
Numerical simulation
Glaucoma
Compatibilidad electromagnética
Dosimetría
Susceptibilidad radiada
Simulación numérica
spellingShingle Glaucoma
Electromagnetic compatibility
Dosimetry
Radiated susceptibility
Numerical simulation
Glaucoma
Compatibilidad electromagnética
Dosimetría
Susceptibilidad radiada
Simulación numérica
Schaumburg, Federico
Estudio de compatibilidad electromagnética de implante ocular activo para tratamiento de glaucoma utilizando métodos computacionales y experimentales
description Fil: Schaumburg, Federico. Universidad Nacional del Litoral. Facultad de Ingeniería y Ciencias Hídricas; Argentina.
author2 Guarnieri, Fabio Ariel
author_facet Guarnieri, Fabio Ariel
Schaumburg, Federico
format Thesis
author Schaumburg, Federico
author_sort Schaumburg, Federico
title Estudio de compatibilidad electromagnética de implante ocular activo para tratamiento de glaucoma utilizando métodos computacionales y experimentales
title_short Estudio de compatibilidad electromagnética de implante ocular activo para tratamiento de glaucoma utilizando métodos computacionales y experimentales
title_full Estudio de compatibilidad electromagnética de implante ocular activo para tratamiento de glaucoma utilizando métodos computacionales y experimentales
title_fullStr Estudio de compatibilidad electromagnética de implante ocular activo para tratamiento de glaucoma utilizando métodos computacionales y experimentales
title_full_unstemmed Estudio de compatibilidad electromagnética de implante ocular activo para tratamiento de glaucoma utilizando métodos computacionales y experimentales
title_sort estudio de compatibilidad electromagnética de implante ocular activo para tratamiento de glaucoma utilizando métodos computacionales y experimentales
publishDate 2017
url http://hdl.handle.net/11185/941
_version_ 1728547937752973312
spelling oai:bibliotecavirtual.unl.edu.ar-handle:11185-9412022-03-23T16:50:27Z Estudio de compatibilidad electromagnética de implante ocular activo para tratamiento de glaucoma utilizando métodos computacionales y experimentales Electromagnetic compatibility study of active ocular implant for treatment of glaucoma using computational and experimental methods Schaumburg, Federico Guarnieri, Fabio Ariel Fraigi, Liliana Beatriz Adur, Javier Fernando Jorge D’Elía Skigin, Diana Carina Glaucoma Electromagnetic compatibility Dosimetry Radiated susceptibility Numerical simulation Glaucoma Compatibilidad electromagnética Dosimetría Susceptibilidad radiada Simulación numérica Fil: Schaumburg, Federico. Universidad Nacional del Litoral. Facultad de Ingeniería y Ciencias Hídricas; Argentina. Glaucoma is a group of optic neuropathies characterized by progressive degeneration of retinal ganglion cells, resulting in progressive loss of vision. The most important risk factor associated with glaucoma is the increased intraocular pressure. US Patent No. 8206440 proposes to treat the disease by lowering intraocular pressure using an active implantable microvalve. This microvalve is powered by means of inductive coupling between two antennae, one located in the implant itself, and the other located in an external device. This powering method brings up, at least, two issues regarding the safety of the microvalve. The former, is the possibility of generating adverse effects on the patient due to exposure to the electromagnetic field required to feed the microvalve. The latter is the possibility of generating adverse effects in the microvalve, and through it in the patient, because of exposure to the electromagnetic fields present in public access areas. These electromagnetic fields are generated by electrical appliances, mobile communication devices and the electric power supply network, among others. The former issue is addressed by a science called dosimetry, while the latter is addressed by radiated susceptibility. Both, dosimetry and radiated susceptibility, can be included inside a broader discipline: the electromagnetic compatibility. In this thesis, dosimetric and radiated susceptibility studies for the microvalve are developed, using mainly computational simulation. El glaucoma es un grupo de neuropatías ópticas caracterizadas por una degeneración progresiva de las células ganglionares retinales, que resulta en una pérdida progresiva de la visión. El factor de riesgo más importante asociado al glaucoma, es la presión intraocular elevada. La patente US 8206440 propone el tratamiento de la enfermedad, disminuyendo la presión intraocular, utilizando una microválvula implantable activa. Esta microválvula se alimenta por medio de un acople inductivo entre dos antenas, una situada en el implante mismo, y la otra situada en un dispositivo externo. Este mecanismo supone, al menos, dos problemas asociados a la seguridad de la microválvula. El primero, es la posibilidad de generar efectos adversos en el paciente, por la exposición del mismo al campo electromagnético requerido para alimentar la microválvula. El segundo problema es la posibilidad de generar efectos adversos en la microválvula, y a través de ella, en el paciente, por la exposición a los campos electromagnéticos que existen ordinariamente en ámbitos de acceso público. Estos campos electromagnéticos son generados por electrodomésticos, dispositivos de comunicación móvil y la red de suministro eléctrico, entre otros. El primer problema es estudiado por una disciplina llamada dosimetría, mientras que el segundo es estudiado por una disciplina llamada susceptibilidad radiada. Ambas, pueden pensarse incluidas en una disciplina más amplia: la compatibilidad electromagnética. En esta tesis se desarrolla un estudio dosimétrico y de susceptibilidad radiada para la microválvula, utilizando principalmente simulación computacional. Consejo Nacional de Investigaciones Científicas y Técnicas Agencia Nacional de Promoción Científica y Tecnológica 2017-05-04 2019-04-02 2017-03-27 info:eu-repo/semantics/doctoralThesis info:ar-repo/semantics/tesis doctoral info:eu-repo/semantics/acceptedVersion SNRD http://hdl.handle.net/11185/941 spa spa info:eu-repo/semantics/openAccess Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) http://creativecommons.org/licenses/by-nc-nd/4.0/deed.es application/pdf
score 11.8626